Purpose: To examine the interday reliability and usefulness of a reactive strength index (RSI) derived from a maximal 5-rebound jump test (5max RJT) and a maximal 10-rebound jump test (10/5 RJT). Methods: Twenty male field-sport athletes (24.5 [3.0] y, 1.78 [0.1] m, 84.9 [5.2] kg) and 15 female participants (21.1 [0.9] y, 1.65 [0.73] m, 62.0 [5.1] kg) performed 2 maximal repetitions of the 5max RJT and the 10/5 RJT on 2 testing days after a specific warm-up. A 1-wk period separated testing days, and these sessions were preceded by a familiarization session. RSI was calculated by dividing jump height (in meters) by contact time (in seconds). The 5max RJT and the 10/5 RJT trial with the highest RSI on each testing day were used for reliability and usefulness analysis. Results: Both tests were deemed reliable for determining RSI for male, female, and pooled male and female cohorts, as the intraclass correlation coefficients were ≥.80 and the coefficient of variation was ≤10%. Only the 5max RJT was rated as “good” at detecting the smallest worthwhile change in performance for female athletes (smallest worthwhile change: 0.10 > typical error: 0.07). The 5max RJT for men and the 10/5 RJT for men and women were rated “good” in detecting a moderate change in performance only. Conclusions: Both tests are reliable for the determination of RSI, but the usefulness of the tests in detecting the smallest worthwhile change is questionable.