Purpose: To assess the reliability and construct validity of a self-paced, submaximal run test (SRTRPE) for monitoring aerobic fitness. The SRTRPE monitors running velocity (v), heart rate (HRex), and blood lactate concentration (B[La]), during three 3-minute stages prescribed by ratings of perceived exertion (RPEs) of 10, 13, and 17. Methods: Forty (14 female) trained endurance runners completed a treadmill graded exercise test for the determination of maximal oxygen consumption (VO2max), v at VO2max (vVO2max), and v at 2 mmol·L−1 (vLT1) and 4 mmol·L−1 (vLT2) B[La]. Within 7 days, participants completed the SRTRPE. Convergent validity between the SRTRPE and graded exercise test parameters was assessed through linear regression. Eleven participants completed a further 2 trials of the SRTRPE within a 72-hour period to quantify test–retest reliability. Results: There were large correlations between v at all stages of the SRTRPE and VO2max (r range = .57–.63), vVO2max (.50–.66), and vLT2 (.51–.62), with vRPE 17 displaying the strongest associations (r > .60). Intraclass correlation coefficients (ICC3,1) were moderate to high for parameters v (range = .76–.84), HRex (.72–.92), and %HRmax (.64–.89) at all stages of the SRTRPE. The corresponding coefficients of variation were 2.5% to 5.6%. All parameters monitored at intensity RPE 17 displayed the greatest reliability. Conclusions: The SRTRPE was shown to be a valid and reliable test for monitoring parameters associated with aerobic fitness, displaying the potential of this submaximal, time-efficient test to monitor responses to endurance training.