Physical Activity Monitor Accuracy for Overground Walking and Free-Living Conditions Among Pregnant Women

in Journal for the Measurement of Physical Behaviour
Restricted access

Purchase article

USD  $24.95

Student 1 year subscription

USD  $37.00

1 year subscription

USD  $50.00

Student 2 year subscription

USD  $71.00

2 year subscription

USD  $93.00

Purpose: We aimed to determine the step-count validity of commonly used physical activity monitors for pregnancy overground walking and during free-living conditions. Methods: Participants (n = 39, 12–38 weeks gestational age) completed six 100-step overground walking trials (three self-selected “normal pace”, three “brisk pace”) while wearing five physical activity monitors: Omron HJ-720 (OM), New Lifestyles 2000 (NL), Fitbit Flex (FF), ActiGraph Link (AG), and Modus StepWatch (SW). For each walking trial, monitor-recorded steps and criterion-measured steps were assessed. Participants also wore all activity monitors for an extended free-living period (72 hours), with the SW used as the criterion device. Mean absolute percent error (MAPE) was calculated for overground walking and free-living protocols and compared across monitors. Results: For overground walking, the OM, NL, and SW performed well (<5% MAPE) for normal and brisk pace walking trials, and also when trials were analyzed by actual speeds. The AG and FF had significantly greater MAPE for overground walking trials (11.9–14.7%). Trimester did affect device accuracy to some degree for the AG, FF, and SW, with error being lower in the third trimester compared to the second. For the free-living period, the OM, NL, AG, and FF significantly underestimated (>32% MAPE) actual steps taken per day as measured by the criterion SW (M [SD] = 9,350 [3,910]). MAPE for the OM was particularly high (45.3%). Conclusion: The OM, NL, and SW monitors are valid measures for overground step-counting during pregnancy walking. However, the OM and NL significantly underestimate steps by second and third trimester pregnant women in free-living conditions.

Connolly, Dahmen, and Catena are with the Department of Kinesiology and Educational Psychology, Washington State University, Pullman, WA. Campbell is with the Moscow/Pullman OB/GYN, Pullman, WA. Montoye is with the Department of Integrative Physiology and Health Science, Alma College, Alma, MI.

Connolly (c.connolly@wsu.edu) is corresponding author.
  • American College of Obstetricians and Gynecologists. (2015). ACOG Committee Opinion No. 650: Physical activity and exercise during pregnancy and the postpartum period. Obstetrics & Gynecology, 126(6), e135–e142. doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Bassett, D.R. (2012). Device-based monitoring in physical activity and public health research. Physiological Measurement, 33(11), 1769–1783. PubMed ID: 23110847 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Bassett, D.R., Toth, L.P., LaMunion, S.R., & Crouter, S.E. (2017). Step counting: A review of measurement considerations and health-related applications. Sports Medicine, 47(7), 1303–1315. PubMed ID: 28005190 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Beevi, F.H., Miranda, J., Pedersen, C.F., & Wagner, S. (2016). An evaluation of commercial pedometers for monitoring slow walking speed populations. Telemedicine Journal and e-Health, 22(5), 441–449. PubMed ID: 26451900 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Borodulin, K.M., Evenson, K.R., Wen, F., Herring, A.H., & Benson, A.M. (2008). Physical activity patterns during pregnancy. Medicine & Science in Sports & Exercise, 40(11), 1901–1908. PubMed ID: 18845974 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Boyer, G., Lachmann, N., Bellemere, G., De Belilovsky, C., & Baudouin, C. (2018). Effects of pregnancy on skin properties: A biomechanical approach. Skin Research and Technology, 24(4), 551–556. PubMed ID: 29479745 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Catena, R.D., Campbell, N., Werner, A.L., & Iverson, K.M. (2019). Anthropometric changes during pregnancy provide little explanation of dynamic balance changes. Journal of Applied Biomechanics, 35(3), 232–239. PubMed ID: 30860422 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Connolly, C.P., Coe, D.P., Kendrick, J.M., Bassett, D.R., Jr., & Thompson, D.L. (2011). Accuracy of physical activity monitors in pregnant women. Medicine & Science in Sports & Exercise, 43(6), 1100–1105. PubMed ID: 21085037 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Connolly, C.P., Conger, S.A., Montoye, A.H., Marshall, M.R., Schlaff, R.A., Badon, S.E., & Pivarnik, J. (2019). Walking for health during pregnancy: A literature review and considerations for future research. Journal of Sport and Health Science, 8(5), 401–411. PubMed ID: 31534815 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Conway, M.R., Marshall, M.R., Schlaff, R.A., Pfeiffer, K.A., & Pivarnik, J.M. (2018). Physical activity device reliability and validity during pregnancy and postpartum. Medicine & Science in Sports & Exercise, 50(3), 617–623. PubMed ID: 29077641 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Crouter, S.E., Schneider, P.L., & Bassett, D.R., Jr. (2005). Spring-levered versus piezo-electric pedometer accuracy in overweight and obese adults. Medicine & Science in Sports & Exercise, 37(10), 1673–1679. PubMed ID: 16260966 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Crouter, S.E., Schneider, P.L., Karabulut, M., & Bassett, D.R., Jr. (2003). Validity of 10 electronic pedometers for measuring steps, distance, and energy cost. Medicine & Science in Sports & Exercise, 35(8), 1455–1460. PubMed ID: 12900704 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Diaz, K.M., Krupka, D.J., Chang, M.J., Peacock, J., Ma, Y., Goldsmith, J., . . . Davidson, K.W. (2015). Fitbit(R): An accurate and reliable device for wireless physical activity tracking. International Journal of Cardiology, 185, 138–140. PubMed ID: 25795203 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • DiNallo, J.M., Downs, D.S., & Le Masurier, G. (2012). Objectively assessing treadmill walking during the second and third pregnancy trimesters. Journal of Physical Activity & Health, 9(1), 21–28. PubMed ID: 22232501 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Downs, D.S., Chasan-Taber, L., Evenson, K.R., Leiferman, J., & Yeo, S. (2012). Physical activity and pregnancy: Past and present evidence and future recommendations. Research Quarterly for Exercise and Sport, 83(4), 485–502. PubMed ID: 23367811

    • Search Google Scholar
    • Export Citation
  • Downs, D.S., LeMasurier, G.C., & DiNallo, J.M. (2009). Baby steps: Pedometer-determined and self-reported leisure-time exercise behaviors of pregnant women. Journal of Physical Activity & Health, 6(1), 63–72. PubMed ID: 19211959 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Evenson, K.R., Savitz, D.A., & Huston, S.L. (2004). Leisure-time physical activity among pregnant women in the US. Paediatric and Perinatal Epidemiology, 18(6), 400–407. PubMed ID: 15535815 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Evenson, K.R., & Wen, F. (2010). National trends in self-reported physical activity and sedentary behaviors among pregnant women: NHANES 1999–2006. Preventive Medicine, 50(3), 123–128. PubMed ID: 20053370 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Evenson, K.R., & Wen, F. (2011). Prevalence and correlates of objectively measured physical activity and sedentary behavior among US pregnant women. Preventive Medicine, 53(1–2), 39–43. doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Feito, Y., Bassett, D.R., Tyo, B., & Thompson, D.L. (2011). Effects of body mass index and tilt angle on output of two wearable activity monitors. Medicine & Science in Sports & Exercise, 43(5), 861–866. PubMed ID: 20962689 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Feito, Y., Garner, H.R., & Bassett, D.R. (2015). Evaluation of ActiGraph’s low-frequency filter in laboratory and free-living environments. Medicine & Science in Sports & Exercise, 47(1), 211–217. PubMed ID: 24870583 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Flores, D., Connolly, C.P., Campbell, N., & Catena, R.D. (2018). Walking balance on a treadmill changes during pregnancy. Gait & Posture, 66, 146–150. doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Fortune, E., Lugade, V.A., Amin, S., & Kaufman, K.R. (2015). Step detection using multi-versus single tri-axial accelerometer-based systems. Physiological Measurement, 36(12), 2519–2535. PubMed ID: 26595421 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Gilleard, W.L. (2013). Trunk motion and gait characteristics of pregnant women when walking: Report of a longitudinal study with a control group. BMC Pregnancy and Childbirth, 13, 71. PubMed ID: 23514204 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Gyselaers, W., Vonck, S., Staelens, A.S., Lanssens, D., Tomsin, K., Oben, J., . . . Bruckers, L. (2018). Body fluid volume homeostasis is abnormal in pregnancies complicated with hypertension and/or poor fetal growth. PLoS ONE, 13(11), e0206257. PubMed ID: 30383796 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Harrison, C.L., Brown, W.J., Hayman, M., Moran, L.J., & Redman, L.M. (2016). The role of physical activity in preconception, pregnancy and postpartum health. Seminars in Reproductive Medicine, 34(2), e28–e37. PubMed ID: 27169984 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Hawkins, M., Kim, Y., Gabriel, K.P., Rockette-Wagner, B.J., & Chasan-Taber, L. (2017). Sedentary behavior patterns in non-pregnant and pregnant women. Preventive Medicine Reports, 6, 97–103. PubMed ID: 28271028 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Hill, C.C., & Pickinpaugh, J. (2008). Physiologic changes in pregnancy. Surgical Clinics of North America, 88(2), 391–401. PubMed ID: 18381119 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Holbrook, E.A., Barreira, T.V., & Kang, M. (2009). Validity and reliability of Omron pedometers for prescribed and self-paced walking. Medicine & Science in Sports & Exercise, 41(3), 670–674. PubMed ID: 19204582 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Hollman, J.H., Watkins, M.K., Imhoff, A.C., Braun, C.E., Akervik, K.A., & Ness, D.K. (2016). A comparison of variability in spatiotemporal gait parameters between treadmill and overground walking conditions. Gait & Posture, 43, 204–209. PubMed ID: 26481257 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Huberty, J.L., Buman, M.P., Leiferman, J.A., Bushar, J., & Adams, M.A. (2016). Trajectories of objectively-measured physical activity and sedentary time over the course of pregnancy in women self-identified as inactive. Preventive Medicine Reports, 3, 353–360. PubMed ID: 27419036 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Lu, H.L., Lu, T.W., Lin, H.C., & Chan, W.P. (2017). Comparison of body’s center of mass motion relative to center of pressure between treadmill and over-ground walking. Gait & Posture, 53, 248–253. PubMed ID: 28231557 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Ma, Y.C., Ashari, Z.E., Pedram, M., Amini, N., Tarquinio, D., Nouri-Mahdavi, K., . . . Ghasemzadeh, H. (2019). CyclePro: A robust framework for domain-agnostic gait cycle detection. IEEE Sensors Journal, 19(10), 3751–3762. doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • McCrory, J.L., Chambers, A.J., Daftary, A., & Redfern, M.S. (2014). The pregnant “waddle”: An evaluation of torso kinematics in pregnancy. Journal of Biomechanics, 47(12), 2964–2968. PubMed ID: 25108664 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • McParlin, C., Robson, S.C., Tennant, P.W., Besson, H., Rankin, J., Adamson, A.J., . . . Bell, R. (2010). Objectively measured physical activity during pregnancy: A study in obese and overweight women. BMC Pregnancy and Childbirth, 10, 76. PubMed ID: 21114834 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Montoye, A.H.K., Dahmen, J., Campbell, N., & Connolly, C.P. (2019). Accuracy of physical activity monitors for steps and calorie measurement during pregnancy walking. Journal for the Measurement of Physical Behaviour, 2(3), 143–156. doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Montoye, A.H.K., Moore, R.W., Bowles, H.R., Korycinski, R., & Pfeiffer, K.A. (2018). Reporting accelerometer methods in physical activity intervention studies: A systematic review and recommendations for authors. British Journal of Sports Medicine, 52(23), 1507–1516. PubMed ID: 27539504 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Mudd, L.M., Owe, K.M., Mottola, M.F., & Pivarnik, J.M. (2013). Health benefits of physical activity during pregnancy: An international perspective. Medicine & Science in Sports & Exercise, 45(2), 268–277. PubMed ID: 22895379 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Nelson, M.B., Kaminsky, L.A., Dickin, D.C., & Montoye, A.H. (2016). Validity of consumer-based physical activity monitors for specific activity types. Medicine & Science in Sports & Exercise, 48(8), 1619–1628. PubMed ID: 27015387 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Pereira, M.A., Rifas-Shiman, S.L., Kleinman, K.P., Rich-Edwards, J.W., Peterson, K.E., & Gillman, M.W. (2007). Predictors of change in physical activity during and after pregnancy: Project Viva. American Journal of Preventive Medicine, 32(4), 312–319. PubMed ID: 17383562 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Petersen, A.M., Leet, T.L., & Brownson, R.C. (2005). Correlates of physical activity among pregnant women in the United States. Medicine & Science in Sports & Exercise, 37(10), 1748–1753. PubMed ID: 16260976 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Pivarnik, J.M., Chambliss, H.O., Clapp, J.F., Dugan, S.A., Hatch, M.C., Lovelady, C.A., . . . Williams, M.A. (2006). Impact of physical activity during pregnancy and postpartum on chronic disease risk. Medicine & Science in Sports & Exercise, 38(5), 989–1006. doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Pivarnik, J.M., & Mudd, L.M. (2009). Oh baby! Exercise during pregnancy and the postpartum period. ACSM's Health and Fitness Journal,13(3), 8–13.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Rousham, E.K., Clarke, P.E., & Gross, H. (2006). Significant changes in physical activity among pregnant women in the UK as assessed by accelerometry and self-reported activity. European Journal of Clinical Nutrition, 60(3), 393–400. PubMed ID: 16306930 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Schneider, P.L., Crouter, S.E., Lukajic, O., & Bassett, D.R. (2003). Accuracy and reliability of 10 pedometers for measuring steps over a 400-m walk. Medicine & Science in Sports & Exercise, 35(10), 1779–1784. PubMed ID: 14523320 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Silcott, N.A., Bassett, D.R., Jr., Thompson, D.L., Fitzhugh, E.C., & Steeves, J.A. (2011). Evaluation of the Omron HJ-720ITC pedometer under free-living conditions. Medicine & Science in Sports & Exercise, 43(9), 1791–1797. PubMed ID: 21311356 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Sushames, A., Edwards, A., Thompson, F., McDermott, R., & Gebel, K. (2016). Validity and reliability of Fitbit flex for step count, moderate to vigorous physical activity and activity energy expenditure. PLoS One, 11(9), e0161224. PubMed ID: 27589592 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Toth, L.P., Bassett, D.R., Crouter, S.E., Overstreet, B.S., LaMunion, S.R., Park, S., . . . Springer, C.M. (2017). StepWatch accuracy during walking, running, and intermittent activities. Gait & Posture, 52, 165–170. PubMed ID: 27914311 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Toth, L.P., Park, S., Springer, C.M., Feyerabend, M.D., Steeves, J.A., & Bassett, D.R. (2018). Video-recorded validation of wearable step counters under free-living conditions. Medicine & Science in Sports & Exercise, 50(6), 1315–1322. PubMed ID: 29381649 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • U.S. Department of Health and Human Services. (2015). Step it up! The surgeon general’s call to action to promote walking and walkable communities. Washington, DC: U.S. Department of Health and Human Services, Office of the Surgeon General.

    • Search Google Scholar
    • Export Citation
  • Widen, E.M., & Gallagher, D. (2014). Body composition changes in pregnancy: Measurement, predictors and outcomes. European Journal of Clinical Nutrition, 68(6), 643–652. PubMed ID: 24667754 doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
All Time Past Year Past 30 Days
Abstract Views 77 77 27
Full Text Views 5 5 4
PDF Downloads 2 2 2