Effect of Humeral-Elevation Angle on Electromyographic Activity in the Serratus Anterior During the Push-Up-Plus Exercise

in Journal of Sport Rehabilitation

Click name to view affiliation

Ui-jae Hwang
Search for other papers by Ui-jae Hwang in
Current site
Google Scholar
PubMed
Close
,
Oh-yun Kwon
Search for other papers by Oh-yun Kwon in
Current site
Google Scholar
PubMed
Close
,
In-cheol Jeon
Search for other papers by In-cheol Jeon in
Current site
Google Scholar
PubMed
Close
,
Si-hyun Kim
Search for other papers by Si-hyun Kim in
Current site
Google Scholar
PubMed
Close
, and
Jong-hyuck Weon
Search for other papers by Jong-hyuck Weon in
Current site
Google Scholar
PubMed
Close
Restricted access

Context:

The push-up-plus (PP) exercise has been recommended for strengthening of the serratus anterior (SA). Previous studies have investigated the effect of different stability properties of the base of support to adjust the difficulty level of SA muscle-strengthening exercises in the PP position. However, the optimal humeral-elevation angle (HEA) for selective activation and maximum contraction of the SA during PP has not been investigated.

Objectives:

To assess the effects of HEA during PP on electromyographic (EMG) activity in the SA, upper trapezius (UT), and pectoralis major (PM) and on the UT:SA and PM:SA activity ratios.

Design:

Comparative, repeated-measures design.

Setting:

University research laboratory.

Participants:

29 healthy men.

Main Outcome Measures:

The subjects performed PP at 3 different HEAs (60°, 90°, and 120°); EMG activity in the SA, UT, and PM was measured, and the UT:SA and PM:SA activity ratios were calculated. Differences in muscle activity and ratios between the 60°, 90°, and 120° HEAs were assessed using 1-way repeated-measures analysis of variance; the Bonferroni correction was applied.

Results:

SA muscle activity was significantly increased, in order of magnitude, at the 120°, 90°, and 60° HEAs. UT:SA and PM:SA activity ratios were significantly greater during performance of the PP at an HEA of 60° than at HEAs of 120° and 90°.

Conclusion:

The results suggest that an HEA of 120° should be used during performance of the PP because it produces greater SA activation than HEAs of 60° and 90°.

Hwang, Kwon, Jeon, and Kim are with the Dept of Physical Therapy, Yonsei University, Wonju, South Korea. Weon is with the Dept of Physical Therapy, Joongbu University, Chungnam, South Korea.

Address author correspondence to Oh-yun Kwon at kwonoy@yonsei.ac.kr.
  • Collapse
  • Expand