Search Results

You are looking at 121 - 130 of 1,162 items for :

Clear All
Restricted access

Kim Beals, Katherine A. Perlsweig, John E. Haubenstriker, Mita Lovalekar, Chris P. Beck, Darcie L. Yount, Matthew E. Darnell, Katelyn Allison and Bradley C. Nindl

Participants A total of 10 male SQT students volunteered to participate in laboratory testing and observation during MWCW training (age = 23.3 ± 1.8 years, height = 182.3 ± 6.4 cm, weight = 83.6 ± 4.5 kg, body fat = 12.5% ± 3.4%, VO 2 max = 60.0 ± 6.8 ml·kg −1 ·min −1 , and heart rate (HR) max = 190.4 ± 8

Restricted access

Stephen A. Ingham, Jamie S. Pringle, Sarah L. Hardman, Barry W. Fudge and Victoria L. Richmond

Purpose:

This study examined parameters derived from both an incremental step-wise and a ramp-wise graded rowing exercise test in relation to rowing performance.

Methods:

Discontinuous step-wise incremental rowing to exhaustion established lactate threshold (LT), maximum oxygen consumption (VO2maxSTEP), and power associated with VO2max (W VO2max). A further continuous ramp-wise test was undertaken to derive ventilatory threshold (VT), maximum oxygen consumption (VO2maxRAMP), and maximum minute power (MMW). Results were compared with maximal 2000-m ergometer time-trial power.

Results:

The strongest correlation with 2000-m power was observed for MMW (r = .98, P < .001), followed by W VO2max (r = .96; P < .001). The difference between MMW and W VO2max compared with the mean of MMW/W VO2max showed a widening bias with a greater difference coincident with greater power. However, this bias was reduced when expressed as a ratio term and when a baseline VO2 was accounted for. There were no differences (P = .85) between measures of VO2maxSTEP and VO2maxRAMP; rather, the measures showed strong association (r = .97, P < .001, limits of agreement = −0.43 to 0.33 L/min). The power at LT and VT did not differ (P = .6), and a significant association was observed (r = .73, P = .001, limits of agreement = −54.3 to 20.2 W, SEE = 26.1).

Conclusions:

This study indicates that MMW demonstrates a strong association with ergometer rowing performance and thus may have potential as an influential monitoring tool for rowing athletes.

Restricted access

Christopher Byrne and Jason K.W. Lee

Declaration of Helsinki. A total of 24 of the 31 participants had complete TC and HR data sets and were included in this study (mean [SD]: age = 26 [3] y; body mass = 65.5 [6.5] kg; height = 1.72 [0.05] m; VO 2 peak = 59 [5] [51–68] mL·kg·min −1 ). Methodology At 4 weeks prior to the race, each individual

Restricted access

Gustavo Monnerat, Alex S. Maior, Marcio Tannure, Lia K.F.C. Back and Caleb G.M. Santos

, VO 2 max, and recovery supported the possibility of genomic predictors affecting trainability. 7 – 11 However, few studies have examined the link between genetic factors within elite soccer players and their physiological and performance parameters. According to our hypothesis, using a complementary

Restricted access

Neil Armstrong

In Volume 1 of Pediatric Exercise Science (PES), a paper by Fenster et al. (25) investigated the relationship between peak oxygen uptake (peak V̇O2) and physical activity (PA) in 6- to 8-year-old children. They used both questionnaires and large-scale integrated activity monitors (LSIs) to estimate daily PA and determined peak V̇O2 using an incremental treadmill test to volitional exhaustion. They concluded that peak V̇O2 correlated well with PA as measured by LSIs but commented that questionnaire data were only weakly and nonsignificantly associated with LSI and peak V̇O2 data. Peak V̇O2 and PA are the most researched and reported variables in the 25-year history of PES. Yet, the assessment and interpretation of young people’s aerobic fitness and PA remain problematic and any meaningful relationship between them during childhood and adolescence is shrouded with controversy. The present paper uses Fenster et al.’s (25) report as an indicator of where we were 25 years ago, outlines how far we have advanced since then, and suggests future directions of research in the study of aerobic fitness and PA.

In the first volume of PES, Fenster et al. (25) investigated the relationship between 6- to 8-year-old children’s peak oxygen uptake (peak V̇O2) and physical activity (PA). Five boys and 13 girls participated in the study and their data were pooled for analysis. Peak V̇O2 was determined during an incremental treadmill test to voluntary exhaustion and PA was estimated using both questionnaires and large-scale integrated activity monitors (LSIs). On the basis of a significant interclass correlation coefficient of r = .59 between peak V̇O2 and the log of LSI average counts per hour Fenster et al. (25) concluded that “aerobic capacity, as measured by peak V̇O2 correlated well with physical activity as measured by LSI” (p.134).

They also commented that questionnaire data were only weakly and nonsignificantly associated with LSI and peak V̇O2 data. Young people’s peak V̇O2 and PA are the most researched and reported variables in the 25-year history of PES and yet the assessment and interpretation of peak V̇O2 and PA and any meaningful relationship between them during growth and maturation are still shrouded with controversy. The present paper uses Fenster et al.’s (25) work as an indicator of our understanding of young people’s peak V̇O2 and PA in 1989, briefly reviews what we know in 2013, and suggests future directions of research.

Restricted access

M. Kathleen Ellis and Lynn A. Darby

This study compared balance and peak oxygen consumption (peak VO2) among hearing, congenital nonhearing, and acquired nonhearing female intercollegiate athletes. Twenty-seven subjects completed two measures of peak VO2 and two measures of balance (static and dynamic). Two pieces of exercise equipment requiring different levels of balance were used: the bicycle ergometer (minimal balance) and the bench-step (maximal balance). Significant differences were found for dynamic balance and for peak VO2 for all subject groups. The significant difference remained among the groups for peak VO2 using the bicycle ergometer when dynamic balance was used as a covariate. There was no significant difference for peak VO2 dependent on type of test when dynamic balance was controlled. The results indicated that dynamic balance affected peak VO2 performance on the bench-step, but not on the bicycle ergometer. These findings suggest that if dynamic balance is required for an assessment of peak VO2, balance should be tested in nonhearing populations.

Restricted access

Han C.G. Kemper, Jos W.R. Twisk and Willem van Mechelen

In the Amsterdam Growth And Health Longitudinal Study (AGAHLS), a group of approximately 650 12- to 14-year-old boys and girls was followed in their growth, and development of their health their lifestyle including diet, physical activity and smoking. One of the main interests was the change in their aerobic fitness. From 12 to 36 years of age in total, eight repeated measurements were performed to measure peak oxygen uptake (peak VO2). In this study the data of peak VO2 are revisited and extended: We made use of all collected data as a mixed longitudinal design including cross-sectionally measured subjects as well as longitudinally measured subjects. This led to the availability of 1,194 boys and 1356 girls. With generalized estimating equations (GEE) the longitudinal changes with chronological age and differences between boys and girls were analyzed. Teenage boys and girls increased their peak VO2 (ml/min) significantly (p < .001) until age 14 in girls and until age 17 in boys. However peak VO2 relative to bodyweight (peak VO2/BW) had significantly (p < .001) decreased over the whole age range from 12 to 36 in both sexes. Vigorous physical activity (VPA) also showed a decrease and was significantly (p < .001) related with lower peak VO2/BW (Beta = 0.001). This relation was stronger in boys than in girls. Because at the start of AGAHLS no fast responding metabolic instruments were available, future longitudinal studies about aerobic fitness should include also measurement of VO2 kinetics.

Restricted access

Lee N. Cunningham

To compare the physiologic differences between adolescent male and female cross-country runners, 12 male and 12 female high school nonelite distance runners who had competed successfully at the All State 5-km championship cross-country meet were tested in the laboratory. Data were analyzed in relation to maximal oxygen consumption (VO2max), ventilatory threshold (VT), and running economy (RE). Male runners were taller, heavier, had less body fat, and ran faster by 2 minutes and 18 seconds than female runners. Running economy was similar between gender. VO2 at a 215 m•min−1 pace was 46.7 ml•kg−1•min−1 for male runners and 47.8 ml•kg−1•min−1 for female runners. At the VT, males demonstrated a higher VO2 and treadmill velocity than females. Heart rate, percent HR max, and percent VO2 max at the VT were not different between gender. Males demonstrated a higher VO2 max of 74.6 versus 66.1 ml•kg−1•min−1 than female runners. The fractional utilization of VO2 at race pace was not different between males (90%) and females (91%). In conclusion, the primary physiologic determinant for performance differences between nonelite, competitive male and female adolescent distance runners is associated with VO2 max.

Restricted access

Juliane R. Fenster, Patty S. Freedson, Richard A. Washburn and R. Curtis Ellison

The relationship between physical activity measured using the LSI (Large Scale Integrated Activity Monitor), and questionnaire, with physical work capacity 170 (PWC 170) and aerobic capacity (peak V̇O2) was evaluated in 6- to 8-year-old children (n = 18). The mean (± SD) peak V̇O2 was 44.1 ± 5.6 ml • kg−1 • min−1. Peak V̇O2 was not significantly different for children (n = 8) who had completed two treadmill trials (45.4 vs. 43.5 ml • kg−1 • min−1; R = 0.67, p<0.05). The log LSI expressed as counts per hour (M ± SD = 2.1 ±.22 cts/hr) was the only activity method significantly related to peak V̇O2 (r = 0.59, p<0.05). The correlation between peak V̇O2 with the questionnaire was positive but nonsignificant (r = 0.20). PWC 170 was not related to peak V̇O2 (r = 0.21) or the activity variables (r = 0.12 questionnaire; r = 0.18 log LSI). When the group was divided into high and low peak V̇O2 groups (high: M = 48.8 ml • kg−1 • min−1; low: M = 39.5 ml • kg−1 • min−1), the log LSI was able to distinguish significant differences in activity levels (high: 2.23 ±. 19 cts/hr; low: 1.99±.19 cts/hr). This study suggests that activity measured with the LSI and aerobic capacity are related in this sample of 6- to 8-year-old children.

Restricted access

Candace D. Perkins, James M. Pivarnik and Matthew R. Green

Background:

The reliability and validity of the SensorMedics VmaxST was tested.

Methods:

Thirty subjects (age = 24.5 ± 4.0 years, height = 174.8 ± 9.8 cm, weight = 70.3 ± 12.6 kg) performed treadmill exercise on three occasions, twice using the VmaxST and once using the SensorMedics 2900 system. Oxygen consumption (VO2; L/min) and heart rate (HR; beats/min) were measured continuously during three, 6- minute stages: 80 m/min, 0% grade; 94 m/min, 5% grade; and 160 m/min, 0% grade, and VO2max.

Results:

Reliability was high, and measurement error was low for VO2 (Rxx range = 0.97 - 0.99, CI = 0.94 - 1.00, SEM = 0.03 - 0.08 L/min) and HR (Rxx = 0.94 - 0.99, CI = 0.88 - 1.00, SEM = 1.8 - 3.2 beats/min). Validity was high for VO2 (Rxy range = 0.92 - 0.98, CI = 0.84 - 0.99, SEE = 0.08 - 0.21 L/min) and HR (Rxy = 0.97 - 0.99, CI = 0.94 - 1.00, SEE = 0.9 - 1.8 beats/min). Mean differences in VO2 between VmaxST and 2900 were small yet significant (P < 0.001).

Conclusions:

The VmaxST demonstrated excellent reliability and validity for measuring VO2 and HR over several exercise intensities. Small overestimates in VO2 by the VmaxST are countered by low measurement error.