The purpose of this investigation was to analyze the validity of an iPhone application (Runmatic) for measuring running mechanics. To do this, 96 steps from 12 different runs at speeds ranging from 2.77–5.55 m·s−1 were recorded simultaneously with Runmatic, as well as with an opto-electronic device installed on a motorized treadmill to measure the contact and aerial time of each step. Additionally, several running mechanics variables were calculated using the contact and aerial times measured, and previously validated equations. Several statistics were computed to test the validity and reliability of Runmatic in comparison with the opto-electronic device for the measurement of contact time, aerial time, vertical oscillation, leg stiffness, maximum relative force, and step frequency. The running mechanics values obtained with both the app and the opto-electronic device showed a high degree of correlation (r = .94–.99, p < .001). Moreover, there was very close agreement between instruments as revealed by the ICC (2,1) (ICC = 0.965–0.991). Finally, both Runmatic and the opto-electronic device showed almost identical reliability levels when measuring each set of 8 steps for every run recorded. In conclusion, Runmatic has been proven to be a highly reliable tool for measuring the running mechanics studied in this work.

Balsalobre-Fernández is with the Department of Sport Sciences, European University of Madrid, Spain. Agopyan and Morin are with LAMHESS, Université Côte d'Azur, Nice, France.

Address author correspondence to Carlos Balsalobre-Fernández at carlos.balsalobre@icloud.com.
Journal of Applied Biomechanics

Article Sections

References

  • 1.

    Moore IS. Is there an economical running technique? a review of modifiable biomechanical factors affecting running economy. Sport Med. 2016;46(6):793807. PubMed doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 2.

    Santos-Concejero JTam NGranados Cet al. Stride angle as a novel indicator of running economy in well-trained runners. J Strength Cond Res. 2014;28(7):18891895. PubMed doi:

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 3.

    Butler RJCrowell HPDavis IM. Lower extremity stiffness: implications for performance and injury. Clin Biomech. 2003;18(6):511517. PubMed doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 4.

    Pappas PParadisis GVagenas G. Leg and vertical stiffness (a)symmetry between dominant and non-dominant legs in young male runners. Hum Mov Sci. 2015;40:273283. PubMed doi:

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 5.

    Barnes KRKilding AE. Running economy: measurement, norms, and determining factors. Sport Med - Open. 2015;1(1):8. PubMed doi:

  • 6.

    Santos-Concejero JOlivan JMate-Munoz JLet al. Gait cycle characteristics and running economy in elite Eritrean and European runners. Int J Sports Physiol Perform. 2015;10(3):381387. doi:

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 7.

    Chapman RFLaymon ASWilhite DPMcKenzie JMTanner DAStager JM. Ground contact time as an indicator of metabolic cost in elite distance runners. Med Sci Sport Exerc. 2012;44(5):917925. PubMed doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 8.

    Buchheit MGray AMorin JB. Assessing stride variables and vertical stiffness with gps-embedded accelerometers: preliminary insights for the monitoring of neuromuscular fatigue on the field. J Sport Sci Med. 2015;14:698701. PubMed

    • Search Google Scholar
    • Export Citation
  • 9.

    Hewit JCronin JHume P. Multidirectional leg asymmetry assessment in sport. Strength Cond J. 2012;34(1):8286. doi:

  • 10.

    Fousekis KTsepis EPoulmedis PAthanasopoulos SVagenas G. Intrinsic risk factors of non-contact quadriceps and hamstring strains in soccer: a prospective study of 100 professional players. Br J Sports Med. 2011;45(9):709714. PubMed doi:

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 11.

    Watari RHettinga BOsis SFerber R. Validation of a torso-mounted accelerometer for measures of vertical oscillation and ground contact time during treadmill running. J Appl Biomech. 2015;11(1):8695. PubMed doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 12.

    Bundle MWPowell MORyan LJ. Design and testing of a high-speed treadmill to measure ground reaction forces at the limit of human gait. Med Eng Phys. 2015;37(9):892897. PubMed doi:

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 13.

    Gindre CLussiana THebert-Losier KMorin J-B. Reliability and validity of the Myotest® for measuring running stride kinematics. J Sports Sci. 2016;34(7):664670. PubMed doi:

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 14.

    Ammann RTaube WWyss T. Accuracy of PARTwear inertial sensor and Optojump optical measurement system for measuring ground contact time during running. J Strength Cond Res. 2016;30(7):20572063. PubMed doi:

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 15.

    Glatthorn JFGouge SNussbaumer SStauffacher SImpellizzeri FMMaffiuletti NA. Validity and reliability of Optojump photoelectric cells for estimating vertical jump height. J Strength Cond Res. 2011;25(2):556560. PubMed doi:

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 16.

    Ruggiero LDewhurst SBampouras TM. Validity and reliability of two field-based leg stiffness devices: implications for practical use. J Appl Biomech. 2016;32(4):415419. PubMed doi:

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 17.

    Morin JBDalleau GKyröläinen HJeannin TBelli A. A simple method for measuring stiffness during running. J Appl Biomech. 2005;21(2):167180. PubMed doi:

  • 18.

    Coleman DRCannavan DHorne SBlazevich AJ. Leg stiffness in human running: comparison of estimates derived from previously published models to direct kinematic-kinetic measures. J Biomech. 2012;45(11):19871991. PubMed doi:

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 19.

    Pappas PParadisis GTsolakis CSmirniotou AMorin JB. Reliabilities of leg and vertical stiffness during treadmill running. Sports Biomech. 2014;13(4):391399. PubMed doi:

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 20.

    Gouttebarge VWolfard RGriek Nde Ruiter CJBoschman JSvan Dieën JH. Reproducibility and validity of the myotest for measuring step frequency and ground contact time in recreational runners. J Hum Kinet. 2015;45:1926. PubMed doi:

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 21.

    Balsalobre-Fernández CGlaister MLockey RA. The validity and reliability of an iPhone app for measuring vertical jump performance. J Sports Sci. 2015;33(15):15741579. PubMed doi:

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 22.

    Gallardo-Fuentes FGallardo-Fuentes JRamírez-Campillo Ret al. Inter and intra-session reliability and validity of the my jump app for measuring different jump actions in trained male and female athletes. J Strength Cond Res. 2015;30(7):20492056. PubMed doi:

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 23.

    Morin JBBelli A. A simple method for measurement of maximal downstroke power on friction-loaded cycle ergometer. J Biomech. 2004;37(1):141145. PubMed doi:

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 24.

    Girard OBrocherie FMorin JBMillet GP. Intra- and inter-session reliability of running mechanics during treadmill sprints. Int J Sports Physiol Perform. 2016;11(4):432439. PubMed doi:

    • Crossref
    • Search Google Scholar
    • Export Citation

Article Metrics

All Time Past Year Past 30 Days
Abstract Views 52 52 41
Full Text Views 0 0 0
PDF Downloads 0 0 0

Altmetric Badge

PubMed

Google Scholar